# LRPR — Filter Pressure Sensor (LRPR-0D6800) **Module ID**: `6a17218be0b88ea3e925524f` **Serial**: `1D00010D68000001` **MAC**: `C8:B9:61:0D:68:00` **UUID**: `1D0058B9610D680000000001000D6800` **Firmware**: 6.3.0 | **Hardware**: A | **Manufacturer**: `1D` **Type**: `lr-pr` **Role**: Measures filter pressure — indicates filter cleanliness / pump running state --- ## Input | Input ID | Type | Unit | Interval | |---|---|---|---| | `6a17218be0b88ea3e9255251` | 8 (pressure) | bar (unit code 6) | 1 min | Raw-to-bar expression: `(1.5 × raw − 500) / 1000` ### Latest readings (2026-06-04) ``` 16:01 0.091 bar ← pump stopped / off 16:00 0.715 bar 15:59 0.741 bar 15:58 0.730 bar 18:41 0.081 bar ← pump off ``` Normal operating pressure ~0.70–0.75 bar. Drop to ~0.08 bar signals pump has stopped. This sensor can be used to detect filtration start/stop and detect dirty filter (rising pressure). --- ## Remote state - Battery: **94%** - Last radio contact: 2026-06-04T20:05:14Z - Relay: `60ca4276ad69dac1558f7c61` (LRMB10) - No programs, no outputs — pure sensor --- ## Pressure Alert Configuration From `poolPressureAlertsVariables` in the input object (retrieved via mobile API): | Parameter | Value | Meaning | |---|---|---| | `staticPressure` | 0.919 bar | Baseline pressure at pump start | | `nominalPressure` | 1.7275 bar | Expected operating pressure | | `maximalPressure` | 1.0615 bar | Upper alert threshold | | `atmosphericPressure` | 1.015 bar | Calibration reference | | `filterCloggedMargin` | 0.5 bar | Rise above static = filter clogged alert | | `filterPreCloggedMargin` | 0.3 bar | Rise above static = pre-clog warning | | `activeFilterCloggedAlert` | true | Filter clog alert enabled | | `activeWaterLevelLowAlert` | true | Low water level alert enabled | | `activeSuctionValveClosedAlert` | true | Suction valve closed alert enabled | | `waterLevelLowCount` | 6 | Ticks below threshold before alert | ## Notes - `secondaryBatteryVoltage: 80` — secondary power source present - Unit code 6 = bar; type 8 = pressure sensor - Backwash reminder alerts fire every ~15 days (shared with pool notebook)