Files
myprimal/api-docs/lrps.md
T
arnaudne 941abd98d5 feat: initial myprimal MQTT bridge service
Dynamic MySolem/MyIndygo IoT bridge with MQTT, Home Assistant
autodiscovery, and Homebridge EasyMQTT compatibility.

- Device discovery via MySolem API on startup (all modules/inputs/outputs)
- Configurable poll engine (fast/normal/slow buckets, per-input overrides)
- MQTT retained state publishing + HA autodiscovery payloads
- Unified manual command routing (linesControl vs sendManualModuleCommand)
- Runtime config via MQTT $config/set, persisted to config.json
- Expression override system (API-provided > hardcoded > passthrough)
- Minimal REST API: /health, /state, /control, /rediscover
- Docker deployment (Dockerfile + docker-compose.yml)
- 38 unit tests

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-28 01:05:24 +02:00

70 lines
1.5 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# LRPS — Pool Analyser / Master Valve (LRPS-0565C0)
**Module ID**: `6480da07c2c0896da120ecca`
**Serial**: `9400030565C00001`
**Type**: `lr-mas`
**Role**: Pool water quality analyser (temperature, pH, ORP/redox)
---
## Inputs
| Input ID | Metric | Type | Unit | Interval |
|---|---|---|---|---|
| `6480da07c2c0896da120eccc` | Water temperature | 5 | °C | ~30 min |
| `6480da07c2c0896da120eccd` | pH | 6 | — | varies |
| `6480da07c2c0896da120ecce` | ORP / Redox | 7 | mV | varies |
### Latest readings (2026-06-04)
**Temperature**
```
19:03 23.43°C
18:03 23.56°C
17:03 23.75°C
16:33 23.87°C
15:33 24.12°C
```
Peak today: 24.62°C at 12:33, cooling through afternoon.
**pH**
```
2026-06-04T01:03 6.35
2026-06-03T12:33 6.30
2026-06-03T03:03 6.35
2026-06-02T18:03 6.30
2026-06-01T20:03 6.25
```
Slowly rising from 5.98 (2026-05-30). Ideal range: 7.27.6. Currently below target.
**ORP / Redox**
```
2026-06-04T16:33 646 mV
2026-06-04T15:33 666 mV
2026-06-04T15:03 661 mV
2026-06-04T14:33 651 mV
2026-06-04T14:03 646 mV
```
Healthy range: 650750 mV. Currently borderline.
---
## Remote state
```
GET /remote/module/state?moduleId=6480da07c2c0896da120ecca
```
- Battery: 60% (low — alerts were sent Feb 2026)
- Last radio contact: 2026-06-04T20:06:55Z
- Relay: `60ca4276ad69dac1558f7c61` (LRMB10)
---
## Alerts (from LRPC maintenance-logs-data)
| Date | Alert |
|---|---|
| 2026-03-18 | Analyzer LRPS-0565C0 needs calibration |
| 2026-02-03 | Battery too low — measurements may be unreliable |